616.10 Product Requirements for Temporary Traffic Control Devices, Pavement Marking and Delineation

From Engineering Policy Guide

Jump to: navigation, search

1) Contractor or manufacturer shall provide a letter of certification stating the device is crashworthy.

2) Contractor or manufacturer shall provide a copy of the FHWA acceptance letter for the device as proof of crashworthiness and a letter certifying the device has essentially the same chemistry, mechanical properties and geometry as that submitted for acceptance.

3) Contractor or manufacturer shall provide a letter of certification stating the device meets MoDOT specifications and standards. Certifications shall identify specific sheeting products used in fabrication of the item.

4) Qualified lists direct which products have been found acceptable for use on MoDOT projects and is not an inclusive listing. Products not listed may be found acceptable for use based on certification.

Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
- - - REFLECTIVE SHEETINGS FOR DELINEATORS 1042 - - - - - X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements
- - - REFLECTIVE SHEETINGS FOR TTCD 1063 - - - - - X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements
606 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
606-30.17 1.00 EACHTYPE C CRASHWORTHY END TERMINAL 606, 1040 - - 3 - X X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements, description is at EPG 1040.4.
606-XX.XX 1.00 EACH WATER-FILLED END TREATMENTS - - - 3 - X - - Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements.
606-66.4X 1.00 EACH GUARDRAIL DELINEATOR606, 1065,1042 606 - - - - X - -
606-66.4X 1.00 EACH GUARD CABLE DELINEATOR 606, 1065,1042 606 - - - - X - -
612 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
612-20.XX 1.00 EACH IMPACT ATTENUATOR612, 1005,1063 612 - 3 - X X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements, description is at EPG 1040.4.
612-30.00 1.00 EACH TRUCK-MOUNTED ATTENUATOR 612, 1063 - - 3 - X X - -
616 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
616-10.05 1.00SQ.FT. CONSTRUCTION SIGNS 616, 1063 616 - - - - X - -
U-CHANNEL POST, 3 LB 616, 903616,903 - - - - X -Galvanization is not required.
WOOD POST, X IN. BY X IN. 616, 903616,903 - - - - X - -
PERFORATED SQUARE STEEL TUBE POST AND ANCHOR SLEEVE 616, 903616,903 - - - - X -Galvanization is not required.
TYPE 1 PORTABLE 616 616 - 2 - X X - Sign substrate used should be consistent with the acceptance and certification letter.
TYPE 2 PORTABLE 616 616 - 2 - X X -Sign substrate used should be consistent with the acceptance and certification letter.
616-10.07 1.00 EACHSPEED LIMIT AND STROBE LIGHT ASSEMBLY 616, 1063 616 - - - - X - -
616-10.08 1.00 EACHADVANCED WARNING RAIL SYSTEM 616, 1063 616 - - - - X - -
616-10.09 1.00 EACHFLAG ASSEMBLY 616, 1063 616 - - - - X - -
616-10.20 1.00 EACH CHANNELIZER (DRUM-LIKE) 616, 1063 616 -1 X -X - -
616-10.21 1.00 EACH CHANNELIZER (DRUM-LIKE) W/LIGHT 616, 1063 616 - 1 X - X - -
616-10.25 1.00 EACH CHANNELIZER (TRIM-LIKE) 616, 1063 616 - 1 X - X - -
CHANNELIZER (CONES) 616, 1063 616 - 1 X - X - -
616-10.30 1.00 EACH TYPE 3 MOVEABLE BARRICADE 616, 1063 616 - 2 - X X - -
616-10.30 1.00 EACHTYPE 3 MOVEABLE BARRICADE W/LIGHT AND/OR SIGN 616, 1063 616 - 2 - X X - -
616-10.33 1.00 EACHDIRECTIONAL INDICATOR BARRICADE 616, 1063 616 - 2 - X X - -
616-10.34 1.00 EACHDIRECTIONAL INDICATOR BARRICADE W/LIGHT 616, 1063 616 - 2 - X X - -
616-10.40 1.00 EACH FLASHING ARROW PANEL 616, 1063 616 - 4 - - X - -
616-10.47 1.00 EACH TYPE 3 OBJECT MARKER 616, 1063 616 - - - - X - -
616-10.51 1.00 EACH WARNING LIGHT, TYPE A 616 616 - - - - X - -
616-10.52 1.00 EACH WARNING LIGHT, TYPE B 616 616 - - - - X- -
616-10.53 1.00 EACH WARNING LIGHT, TYPE C 616 616 - - - - X - -
616-10.70 1.00 EACH TUBULAR MARKER 616, 1063 616 - 1 X - X - -
616-10.95 1.00 EACH RADAR SPEED ADVISORY SYSTEM 616, 1063 - - 4 - - X - -
616-10.98 1.00 EACHCHANGEABLE MESSAGE SIGN 616, 1063 616 - 4 - - X - -
616-11.00 1.00 EACHCHANGEABLE MESSAGE SIGN, CONTRACTOR FURNISHED,COMMISSION RETAINED 616, 1063 616 - 4 - - X X -
616-20.00 1.00 EACHWORK ZONE TRAFFIC SIGNALS (PORTABLE OR TEMPORARY SPAN) 616, 1063 - - 4 for trailer - - X - -
616-20.101.00LUMP SUM WORK ZONE LIGHTING 616 - - 4 for trailer - - X - Lighting Plans are Required
VERTICAL PANELS - - - 2 - X - - Experimental Basis
617 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
617-36.XX 1.00LINEAR FTTEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/RETAINED (ALL COMBINATIONS)617, 1064, 1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-36.XX 1.00LINEAR FTTEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/COMMISSION RETAINED (ALL COMBINATIONS)617, 1064, 1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-40.00 1.00 EACHTEMPORARY CONCRETE BARRIER HEIGHT TRANSITION617, 1064,1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-80.0X 1.00 EACH TRAFFIC BARRIER DELINEATOR617, 1065,1042 617 - - - - X - -
617-XX.XX - - WATER FILLED BARRIER - - - 3 - X - - -
617-XX.XX - -TEMPORARY GLARE SCREENS - - - - - - - - -
620 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
620-XX.XX 1.00LINEAR FT OR EACH TYPE 1 PREFORMED TAPE 620, 1048 620 - - - - X X -
620-51.XX 1.00LINEAR FT OR EACH TYPE 2 PREFORMED TAPE 620, 1048 620 - - - - X X -
620-53.XX 1.00LINEAR FT PREFORMED REMOVABLE MARKING TAPE 620, 1048 620 - - - - X X -
620-53.XX 1.00LINEAR FT OR EACHPREFORMED SHORT TERM MARKING TAPE 620, 1048 620 - - - - X X -
620-59.XX 1.00LINEAR FTHIGH BUILD ACRYLIC WATERBORNE PAVEMENT MARKING PAINT 620, 1048 620 - - - - X X -
620-6X.XX 1.00LINEAR FT OR EACHACRYLIC WATERBORNE PAVEMENT MARKING PAINT 620, 1048 620 - - - - X XBeing phased out due to the use of high build acrylic waterborne pavement marking paint.
620-6X.XX1.00LINEAR FT OR EACHACRYLIC COPOLYMER FAST DRY PAVEMENT MARKING PAINT 620, 1048 620 - - - - X X -
620-62.XX1.00LINEAR FT OR EACHTYPE A EPOXY PAVEMENT MARKING 620, 1048 620 - - - - X X -
620-63.XX 1.00LINEAR FT OR EACHTYPE B EPOXY PAVEMENT MARKING 620, 1048 620 - - - - X X -
620-80.64 1.00 EACHTEMPORARY RAISED PAVEMENT MARKER, TYPE 1 620, 1048 620 - - - - X X -
620-80.651.00 EACHTEMPORARY RAISED PAVEMENT MARKER, TYPE 2 620, 1048 620 - - - - X X -
DROP-ON GLASS BEADS 620, 1048 - - - - - X X -
CURB SYSTEMS - - - 2 - X - - -
902 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
902-94.12 1.00 EACHWORK ZONE TRAFFIC SIGNALS (PORTABLE), CONTRACTOR FURNISHED, COMMISSION RETAINED 616, 1063 - - 4 - - X X -


Personal tools